AR68.80-L-4830VA | Disassemble, assemble pull-out cargo area floor | 17.3.10 |
MODEL 414.700 with CODE (YG7) Pull-out cargo area floor
L68.20-0007-09
1 Floor plate
2 Frame
3 Left telescopic rail
4 Screw
5 Right telescopic rail
6 Screw
7 Slide
8 Bolt
9 Screw socket
10 Left cover
21 Bolt mount
22 Left control cable
23 Right control cable
24 Felt strip
25 Catch
26 Nut
11 Front cover
12 Right cover
13 Rear cover
14 Spring
15 Release handle
16 Screw socket
17 Spacer washer
18 Spring mount
19 Spring
20 Thrust piece
| Disassemble/assemble | ||
Danger! | Risk of injury. Moving parts can pinch, crush or, in extreme cases even sever extremities. | Keep body parts and limbs well clear of moving parts. | |
1 | Remove cargo space floor and lay down on work bench with top down | See Operating Instructions | |
2 | Unscrew bolts (6) in area of telescopic rail (3, 5) | Replace self-locking bolts (6). | |
3 | Unscrew spring mounts (18) and remove | When removing frame (2) remove only spring mounts (18) in area of telescopic rails (3, 5) | |
4 | Remove springs (19) and thrust pieces (20) from bolt mounts (21) | ||
5 | Remove spacers (17) | In area of telescopic rail (3, 5) | |
6 | Actuate release handle (15) and slide frame (2) back | The frame (2) should be released from the floor plate (1) to remove | |
7 | Remove frame (2) from floor plate (1) | ||
8 | Unscrew screws (4) and remove telescopic rail (3, 5) from frame (2) | ||
9 | Unscrew bolts (8) from slide (7) | Replace self-locking bolts (8). | |
10 | Pull back slide (7) and unscrew screw sockets (16) | Avoid damage. | |
11 | Remove rear cover (13) from floor plate (1) | ||
12 | Remove springs (14) from release handle (15) | ||
13 | Unhook control cables (22, 23) from release handle (15) | Installation: The catch hooks of the control cables (22, 23) should catch audibly. | |
14 | Remove release handle (15) | ||
15 | Unclip control cables (22, 23) from slide (7) | ||
16 | Unscrew nuts (26) | ||
17 | Pull catches (25) out of slide (7) | Installation: Clean thread of catches (25) and apply locking compound. | |
18 | Remove slide (7) from floor plate (1) | ||
19 | Loosen strips of felt (24) and remove control cables (22, 23) | Check control cables (22, 23) for damage, replace if necessary. | |
20 | Unscrew screw sockets (16) | In area of covers (10, 11, 12) | |
21 | Drive out bolt mounts (21) and remove | Avoid damage, use suitable subsurface and tool. | |
22 | Remove covers (10, 11, 12) | ||
23 | Assemble in reverse order |
Repair materials
Number | Designation | Order number |
BR00.45-Z-1040-02A | Adhesive fastening, Loctite 648 | A 003 989 32 71 |
Powiązane dokumenty