ar6510p100003fr

Prepare center roof paneling for installation

Typ ar · temat 65.10 · wersja 0100 · 2018-04-19

Dotyczy: Model 257

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 65 Dach › 65.10 Poszycie dachu — Seria 257

EinPAS 35 Karoseria/ rama/ elementy domontowane › 35.39 Dach › 35.39.30 Poszycie/rama dachu — Seria 257

AR65.10-P-1000-03FR

Prepare center roof paneling for installation

Model

257

The following steps are shown on model 257 except for code 414 (sliding roof).
Observe the higher-level service document as well as the safety information in the service document.

Prepare center roof paneling for installation

1

Prepare bonding surfaces on center roof paneling (1) down to bare metal in crosshatched areas (areas B).


Observe processing specifications of adhesive.



2

Grind mating surfaces down to bare metal in remaining crosshatched areas.


Sand down spot weld flanges to bare metal on both sides.



3

Remove grinding dust.



4

Coat insides of spot weld flanges with zinc dust paint.


Do not coat bonding surfaces with zinc dust paint (areas A).
Otherwise adhesion problems may occur.


Observe pretreatment of bonding surfaces.


P65.10-3795-06