222 589 01 31 00
Set of shields
Further information can be found in the superordinate service document.
The safety information in the superordinate service document must be observed.
1 | Remove screws (3). |
2 | Remove nuts (2) and remove roof frame mounting supports. |
P65.10-A148-05
P65.10-A147-09
3 | Insert cutting wire at point (B) through adhesively bonded connection (hatched area). |
4 | Cut adhesively bonded connection (hatched area) starting at the starting point (B), in both directions up to the end point (C). |
Carefully cut adhesively bonded connection (hatched area). |
Helper required. |
Protect adjacent surfaces with shield plates during cutting procedure. |
5 | Lift carbon roof (1) with suction lifters and remove. |
Helper required. |