MODEL | 909 |
1 | Mark separation line (2) on right B-pillar paneling (1) at top. |
Dimensions: |
D63.20-0045-02
2 | Mark separation line (3) on right B-pillar paneling (1) at bottom. |
Dimensions: |
D63.20-0046-11
3 | Expose spot welds on right B-pillar paneling (1) up to marked separation line (2) and cut out (area A and B). |
4 | Separate right B-pillar paneling (1) at marked separation line (2). |
D63.20-0047-03
5 | Expose spot welds on right B-pillar paneling (1) up to marked separation line (3) and cut out (area A, B and C). |
6 | Separate right B-pillar paneling (1) at marked separation line (3). |
7 | Remove right B-pillar paneling (1). |
8 | Grind mating surfaces down to bare metal. |
Sand down spot weld flanges to bare metal on both sides. |
9 | Remove grinding dust. |
10 | Coat inside of spot welding flanges with zinc dust paint. |
D63.20-0048-06