AR63.10-D-0020-03TS | Install and weld in front side wall paneling | ||
Danger | The high voltage used for electric welding presents a lethal hazard. Risk of explosion from welding in areas close to highly inflammable materials. Risk of injury from weld splatter and UV-light when welding. Risk of poisoning from inhaling welding gases | Use insulating mats. Wear protective clothing, safety glasses and a protective mask. Remove highly inflammable materials from the hazard area. Use air extraction system. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | Measures for preventing damage to vehicles or components when performing electric welding work | ||
| 000 588 01 84 00 Welder | ||
| 000 588 02 84 00 Welder |
906 589 01 23 00
Set of templates
The following operation steps are shown on model 907.633 with code D03 (Roof and rear-end doors, high version) on the left side of vehicle and must be performed analogously on the right side of vehicle if damaged.
D63.10-1962-07
1 | Apply seam seal in hatched areas. |
2 | Model 907.6 without window in side wall, model 910.6 without window in side wall |
See Fig. A. |
D63.10-1949-02
D63.10-1958-08
3 | Install, fit and fix in place front side wall paneling (1). |
Use set of templates to fit front side wall paneling (1) to center side roof paneling. |
4 | Model 907.6/7 with window in side wall, model 910.6 with window in side wall |
5 | Tack weld front side wall paneling (1) (areas O and Q). |
6 | Surface-grind inert-gas tack welds (areas O and Q). |
D63.10-1959-09
7 | Front side wall paneling (1) (areas R and S). |
8 | Front side wall paneling (1) (areas T). |
9 | Front side wall paneling (1) (area U). |
10 | Surface-grind inert-gas plug welds on front side wall paneling (1) (area T). |
D63.10-1960-06
11 | Front side wall paneling (1) (areas V). |
D63.10-1961-06
Powiązane dokumenty
- ah0000n000501a Zabezpieczenia zapobiegające uszkodzeniom pojazdu lub jego elementów podczas spawania elektrycznego
- as0000z000701a Zagrożenie dla życia przez wysokie napięcie przy spawaniu elektrycznym. Niebezpieczeństwo wybuchu podczas spawania w pobliżu materiałów łatwopalnych. Niebezpieczeństwo urazu na skutek odprysków przy spawaniu oraz promieniowania u
- as0000z001701a Niebezpieczeństwo obrażeńo elementy pojazdu o ostrych krawędziach.
- ws6000p0021k
- ws6000p0022k