ar5465s0030p

Remove/install backup camera

Typ ar · temat 54.65 · wersja 0102 · 2020-06-16

Dotyczy: Model 470, 471 with code FR8 (Rear view camera) Model 470 with code JS1 (360° camera (SURROUND VIEW))

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 2 Podwozie › 54 Instalacja elektryczna, wyposażenie i wskaźniki › 54.65 Wspomaganie parkowania — Seria 470 · Seria 471

EinPAS 36 Widoczność › 36.25 System kamery › 36.25.30 Kamera obszaru zewnętrznego — Seria 470 · Seria 471

AR54.65-S-0030P

Remove/install backup camera

16.06.2020

Model

470, 471

with code FR8 (Rear view camera)

Model

470

with code JS1 (360° camera (SURROUND VIEW))

Remove/install backup camera

S54.65-4701-08

Shown on model 470 with code FR8 (Reversing camera)

1

Electrical connector

3

Backup camera

5

Electrical connector

2

Screw

Remove/install backup camera

Shown on model 470 with code FR8 (Reversing camera)

3

Backup camera

4

Bracket

S54.65-4695-04

Warning

Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof.

No parts of the body or limbs should be within the operating area when the components are moving.

AS00.00-Z-0011-01A

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Remove/install

1

Read out and temporarily store basic data from reversing camera (3).

If the reversing camera (3) is to be replaced.

Installation: Transfer buffered basic data and perform initial startup of reversing camera (3).

2

Switch off ignition and store transmitter key outside of transmission range (min. 2  m).

3

Remove inner cover from rear dropside.

AR60.30-S-0016-01P

4

Disconnect electrical connector (1).

5

Disconnect electrical connector (5).

Model 470, 471
with code FR8 (Rear view camera)

6

Unscrew screws (2) and take reversing camera (3) out of rear dropside.

7

Unclip reversing camera (3) from holder (4) (arrows) and remove holder (4).

If the reversing camera (3) is to be replaced.

8

Install in the reverse order

9

Calibrate reversing camera (3).

AD00.00-S-2000-06P

Check

10

Perform function check of reversing camera (3).

Powiązane dokumenty