S54.65-4696-08
Shown on left outer PARKTRONIC sensor (2) on model 470 |
1 | Electrical connector | 3 | Bracket | 4 | Seal | ||
2 | PARKTRONIC sensor |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Disconnect electrical connector (1) | ||
2 | Release catch hook in direction of arrow and pull PARKTRONIC sensor (2) forwards out of the holder (3) | ||
3 | Check seal (4) for signs of damage and correct seating | If seal (4) is damaged. | |
| |||
Install new seal (4). | |||
If the seal (4) is not correctly seated on the PARKTRONIC sensor (2). | |||
| |||
Correctly position seal (4). | |||
4 | Install in the reverse order | ||
| Check | ||
5 | Perform function check for PARKTRONIC |
Powiązane dokumenty
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego