1 | Electrical connector |
2 | Mounting clip |
3 | Cover |
N80 | Steering column module control unit |
P54.26-1356-05
4 | Steering column tube |
N80 | Steering column module control unit |
P54.21-3966-05
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Carry out commissioning of steering column tube module control unit (N80). | If steering column tube module control unit (N80) is replaced. | |
| |||
2 | Remove steering wheel. | ||
Installation: After installation of a new steering column tube module control unit (N80), transport protection must be broken off before installing the steering wheel. | |||
3 | Remove steering column tube module control unit (N80) from steering column tube (4) until cover (3) can be unclipped. | Installation: When the installation position of the steering column tube module control unit (N80) is correct, the assembly indicator is retracted. | |
4 | Unclip cover (3) from steering column tube module control unit (N80). | ||
5 | Remove steering column tube module control unit (N80) from steering column tube (4) until the electrical connector (1) and retaining clip (2) are accessible. | | |
| |||
The steering column tube module control unit (N80) contains the clock spring contact, the steering angle sensor and the switch panel. It is one component and can only be removed or replaced complete. | |||
6 | Unclip retaining clip (2). | Dismantling tool | |
7 | Remove actuator lock of electrical connector (1). | Installation: Replace actuator lock of electrical connector (1). | |
8 | Release electrical connector (1), disconnect, and remove steering column tube module control unit (N80). | ||
9 | Install in the reverse order | ||
Concluding tasks | |||
10 | Carry out initialization of DISTRONIC electric controller unit. | Model 118, 177, 247 | |
|
000 589 95 63 00
Dismantling tool
Powiązane dokumenty
- ad0000p200006mfa
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ar4610p0100mfa