P54.25-3467-04
1 Shackle
2 Plug-in wiring plug connection
S4 Combination switch
| Remove/Install | ||
1 | Remove instrument cluster | ||
2 | Press lug (1) inwards and remove combination switch (S4) from the upper bearing shell | When removing the right lever switch (S4) ensure that the predetermined fracture point on the upper bearing shell is not damaged (arrow). When replacing the combination switch (S4) transfer end cap. | |
3 | Disconnect electrical connector (2) from combination switch.S4 | Do not damage catch lugs, otherwise connector can no longer lock. Installation: Observe arrest of electrical connector (2). | |
4 | Install in the reverse order |