P80.20-2612-09
| Remove | ||
1 | Separate sheath of wiring harness for pneumatic control unit with combined functions (A37) | At the height of the longitudinal member. | |
2 | Separate wiring harness for pneumatic control unit with combined functions (A37) | Above the longitudinal member (arrows). | |
3.1 | Separate sheath of wiring harness for anti-theft alarm system (ATA) to pneumatic control unit with combined functions (A37) | Valid for anti-theft alarm system (ATA) code 551a | |
4.1 | Separate wiring harness for anti-theft alarm system ATA to pneumatic control unit with combined functions (A37) | Valid for anti-theft alarm system (ATA) code 551a | |
5 | Separate pneumatic lines | Above the longitudinal member (arrows). | |
| Install | ||
6 | Prepare wiring harness from package contents | ||
7 | Connect repair wiring harness with original wiring harness by means of solder connector | ||
8 | Extend pneumatic lines with rubber sleeve | Press pneumatic line at least 10 cm into the rubber sleeve so that the leaktightness of the repair point is guaranteed. | |
9 | Wrap the repair point after the line repair | Using fabric tape. |
Powiązane dokumenty
- ar0019p010008a Zabezpieczanie miejsca naprawy po naprawie przewodu
- ar0019p010009a Naprawa wiązki przewodów za pomocą łączników lutowanych
- ar5418p090001g