ar5410s6575e

Remove/install interior 230V socket without grounding contact

Typ ar · temat 54.10 · wersja 0101 · 2019-11-19

Dotyczy: Model 447.8 with code ZK7 (Equipment line MARCO POLO)

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 2 Podwozie › 54 Instalacja elektryczna, wyposażenie i wskaźniki › 54.10 Akumulator, zasilanie, przetwornik napięcia — Seria 447 (modele 8**)

EinPAS 25 Instalacja elektryczna/sieć wymiany danych/wielofunkcyjne › 25.20 Sieć pojazdu › 25.20.50 Gniazdo/punkt masowy/punkt podłączania zewn. źródła rozruchu — Seria 447 (modele 8**)

AR54.10-S-6575E

Remove/install interior 230V socket without grounding contact

18.11.2019

Model

447.8

with code ZK7 (Equipment line MARCO POLO)

Remove/install interior 230V socket without grounding contact

Shown on MODEL 447.8 with CODE LC0 (Marco Polo cabinet module ambiance illumination)

1

Kitchen module ambiance illumination switch

2

USB connection

3

Cover

X58/24

230 V socket

X58/25

230 V socket voltage converter

S54.10-4644-06

Danger

Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)

Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.

AS00.00-Z-0035-01A

Topical note

Notes on carrying out repair work in the vehicle interior

AH68.00-N-0001-01S

Remove/install

1

Remove kitchen module ambiance illumination switch (1)

Model 447.8
with code LC0 (Ambient lighting, Marco Polo cabinet module)
with code ZK7 (Equipment line MARCO POLO)

AR82.20-S-0122E

2

Remove 230 V (X58/24) socket

AR54.10-S-6574E

3

Remove USB connector (2) in rear

AR82.60-S-1034E

4

Loosen trim (3) in the upper area, take it out of the lower guide and remove until the electric plug connection of the 230 V socket voltage converter (X58/25) is accessible

5

Disconnect electrical connector from 230 V socket voltage converter (X58/25)

6

Release catches (arrows) of 230 V socket voltage converter (X58/25) and remove 230 V socket voltage converter (X58/25) from trim (3)

7

Install in the reverse order

Check

8

Perform function check on 230 V socket voltage converter (X58/25)

Powiązane dokumenty