ar5410s1129a

Check condition of battery

Typ ar · temat 54.10 · wersja 0113 · 2012-02-22

Dotyczy: MODEL 638.0 /1 /2

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 2 Podwozie › 54 Instalacja elektryczna, wyposażenie i wskaźniki › 54.10 Akumulator, zasilanie, przetwornik napięcia — Seria 638 (modele 0**, 1**, 2**)

EinPAS 25 Instalacja elektryczna/sieć wymiany danych/wielofunkcyjne › 25.20 Sieć pojazdu › 25.20.20 Akumulator — Seria 638 (modele 0**, 1**, 2**)

AR54.10-S-1129A

Check condition of battery

15.2.12

MODEL 638.0 /1 /2

Check condition of battery

P54.10-0004-06

Check condition of battery

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Visual inspection for external leaks

If leaks are present

Replace battery.

AR54.10-S-0005A

Dispose of battery in an environmentally-compatible manner.

OS54.10-N-0001-01A

2

Unscrew cell cap

3

Measure acid density

Battery electrolyte tester

If the electrolyte density in a cell deviates by more the permissible difference from the others.

Battery capacity 66 Ah

*BE54.10-N-1005-01A

Battery capacity 88 Ah

*BE54.10-N-1009-01A

Replace battery

AR54.10-S-0005A

Dispose of battery in an environmentally-compatible manner.

OS54.10-N-0001-01A

Acid density below minimum value

Charge battery.

AR54.10-S-1130A

4

Check fluid level

If necessary, refill with distilled water.

5

Screw in cell cap (2)

Battery/power supply test and adjustment values

Number

Designation

All models

BE54.10-N-1005-01A

Battery capacity 66 Ah

Battery test at 20 °C

Acid density (battery charged)

kg/dm3

1,28

Acid density during status test

kg/dm3

1,24


Permissible deviation of individual cells

kg/dm3

0,04

Cold test current

in accordance with DIN

A

300

as per EN

A

510

BE54.10-N-1009-01A

Battery capacity 88 Ah

Battery test at 20 °C

Acid density (battery charged)

kg/dm3

1,28

Acid density during status test

kg/dm3

1,24


Permissible deviation of individual cells

kg/dm3

0,04

Cold test current

in accordance with DIN

A

400

as per EN

A

680