1 | Bolts |
2 | Connection |
3 | Cover |
4 | Electrical wiring harness |
X58/23 | 230 V feed socket |
S54.10-4668-06
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
| Remove/install | ||
1 | Switch off ignition and remove transmitter key | ||
2 | Open cover on connection (2) | ||
3 | Remove charger plug from 230 V socket (X58/23) | If connected. | |
4 | Remove bolts (1) | ||
5 | Pull 230 V feed socket (X58/23) out of connection (2) until cover (3) can be removed | ||
6 | Detach cover (3) | ||
7 | Remove electrical wiring harness (4) from 230 V feed socket (X58/23) and remove 230 V feed socket (X58/23) | Observe connection schematic for electrical wiring harness (4). | |
8 | Install in the reverse order | ||
| Check | ||
9 | Connect charger plug to 230 V socket (X58/23) and check 230 V socket (X58/23) for proper function | Read off the charging voltage from the central electronics display unit in the cockpit. |
Powiązane dokumenty
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne