1 | Electrical connection |
2 | Nut |
3 | Electrical line |
4 | Electrical line |
B95 | Battery sensor |
S54.10-4600-11
| Remove/install | ||
Danger | Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
1 | Disconnect battery ground line | ||
2 | Disconnect electrical connection (1) | ||
3 | Remove electrical lines (3, 4) | Unscrew nut (2) to do this. | |
Nut, ground line to negative terminal/battery sensor | |||
4 | Remove battery sensor (B95) | The battery sensor (B95) is integrated in the ground line and cannot be replaced separately. | |
5 | Install in the reverse order |
Powiązane dokumenty
- ah5410p000101a Wskazówki dotyczące akumulatora
- ah5410p000101a
- ar5410s0003c Odłączanie, podłączanie przewodu masowego akumulatora
- as5410z000101a Niebezpieczeństwo pożaru/wybuchu z powodu zwarcia i wydostającego się gazu piorunującego. Niebezpieczeństwo obrażeń z powodu poparzenia oczu, skóry i śluzówki przez elektrolit akumulatora/mgiełkę lub przez zwarcie i działanie