P54.10-A046-08
Shown on model 293 ### 1# |
1 | Electrical connector | 3 | Bolts | |
2 | Electrical connector | F63 | Pyrofuse |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Remove trim below instrument panel on passenger side. | ||
2 | Detach ground line of on-board electrical system battery. | ||
3 | Unscrew bolts (3). | ||
4 | Pull pyrofuse (F63) downwards until electrical connectors (1, 2) are accessible. | ||
5 | Disconnect electrical connectors (1, 2). | ||
6 | Remove pyrofuse (F63). | ||
7 | Install in the reverse order | ||
8 | Read out and delete fault memory. | ||
|