ar5410p1129ff

Check condition of battery

Typ ar · temat 54.10 · wersja 0103 · 2020-01-30

Dotyczy: Model 454.0

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 2 Podwozie › 54 Instalacja elektryczna, wyposażenie i wskaźniki › 54.10 Akumulator, zasilanie, przetwornik napięcia — Seria 454 (modele 0**)

EinPAS 25 Instalacja elektryczna/sieć wymiany danych/wielofunkcyjne › 25.20 Sieć pojazdu › 25.20.20 Akumulator — Seria 454 (modele 0**)

AR54.10-P-1129FF

Check condition of battery

20.01.2020

Model

454.0

Check

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

1

Read out fault memory

AD00.00-P-2000-04FF

Delete fault memory; rectify faults if necessary.

Commercially available devices/tools
STAR DIAGNOSIS Compact diagnosis system for passenger cars

2

Open hood

3

Visual inspection of battery for external leakage

If leaks are found, battery must be replaced.

Dispose of defective battery properly and in an environmentally compatible manner.

Refer to:

Remove/install battery

AR54.10-P-0005FF

4

Check battery using battery tester and compare measurement result with measurement tables

Topical note

Notes on battery

AH54.10-P-0001-01A

Assess condition of battery based on measurement tables; if necessary:

Battery tester

*450589152100

Charge battery

AR54.10-P-1130FF

Replace battery

AR54.10-P-0005FF

Dispose of defective battery properly and in an environmentally compatible manner.

5

Check fluid level; correct if necessary

Only if battery was not replaced.

AP54.10-P-5410FF

Check condition of battery

450 589 15 21 00

Battery tester

Powiązane dokumenty