1 | Ground cable |
B95 | Battery sensor |
G1 | On-board electrical system battery |
P54.10-4162-03
1 | Ground cable |
3 | Nut |
P54.10-4165-11
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove/install | ||
1 | Detach ground line (1) from on-board electrical system battery (G1) | ||
2 | Detach electrical connector from battery sensor (B95) | ||
3 | Unscrew nuts (3) | Ground line with battery sensor to body | |
4 | Remove ground line (1) with battery sensor (B95) | The ground line (1) and the battery sensor (B95) are one component and cannot be replaced individually. | |
5 | Install in the reverse order |
Powiązane dokumenty
- ah5410p000101a Wskazówki dotyczące akumulatora
- ah5410p000101a
- ar5410p0003rg