Shown on model 907 with code G42 (7G-TRONIC PLUS) |
1 | Voltage converter |
2 | Retaining tabs |
3 | Bracket |
4 | Electrical connectors |
D54.10-1208-06
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on carrying out repair work in the vehicle interior | ||
| Remove/install | ||
1 | Detach ground line of on-board electrical system battery. | ||
2 | Remove lower center stowage compartment at instrument panel. | ||
3 | Release voltage converter (1) at retaining tabs (2) and remove from holder (3) until the electrical connectors (4) are accessible. | ||
4 | Disconnect electrical connectors (4) and remove voltage converter (1). | ||
5 | Install in the reverse order. | ||
| Check | ||
6.1 | Perform function test of 230 V socket. | Model 907, 910 | |
6.2 | Perform function test of 115 V socket. | Model 907.1/6/7 |