Warning | Risk of burn injuries and scalding when working on AdBlue(R) lines and the component parts attached to them. Risk of injury to skin and eyes when handling AdBlue(R). Risk of poisoning caused by swallowing AdBlue(R) | Pour AdBlue® only into suitable containers. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Topical note | Notes on use, material properties and handling of NOx reducing agent | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Draining | |||
1 | Open fuel filler flap. | ||
2 | Remove cap. | | |
3 | Insert extraction hose in AdBlue® tank. | ||
| 000 588 01 71 00 Extraction pump | ||
Observe arrow on the extraction pump indicating the direction of suction. | |||
4 | Suction off AdBlue® with extraction pump and extraction hose out of the AdBlue® container and capture in a suitable container. | Observe the disposal regulations for AdBlue®. | |
5 | Pull extraction hose out of the AdBlue® container. | ||
| Clean | ||
6 | Clean extraction pump and extraction hose. | | |
Filling | |||
7.1 | Fill AdBlue® tank with filling unit. | If the AdBlue® container is filled using the filling unit. | |
| 000 588 07 82 00 Filling unit | ||
| |||
| |||
The filling tools are designed in such a way as to leave an unfilled space in the AdBlue® container after switching off. | |||
AdBlue® tank | |||
7.2 | Fill AdBlue® tank with refill canister. | If the AdBlue® container is filled using refill canisters. | |
| |||
| |||
The one-way filling hose is designed so that an unfilled area remains in the AdBlue® container after the locking mechanism is triggered. | |||
One-way filling hose | |||
10 l can of AdBlue® | |||
20 l can of AdBlue® | |||
AdBlue® tank | |||
8 | Remove the AdBlue® residues. | ||
9 | Attach cap. | ||
10 | Close fuel filler flap. |