AR47.70-S-1030-03G | Perform protective ground conductor and insulation resistance measurement | ||
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Notes on battery | ||
| 000 588 00 19 00 Insulation measuring unit |
Only perform protective ground conductor and insulation resistance measurement after the vehicle has been de-energized.
Otherwise test results will be incorrect.
Never perform the protective ground conductor and insulation resistance test at a high-voltage component between "HV+" (plus) and "HV-" (minus).
Otherwise, the high voltage component will be damaged.
Carefully attach probes of insulation resistance tester to high-voltage connections.
Otherwise the high-voltage connections may be damaged.
S47.70-A044-78
Shown on Economic Commission for Europe (ECE) charger feed-in socket (type 2) (alternating current) |
1 | AC charger feed-in connection | L3 | Phase L3 | |
2 | Attachment point | N | Neutral conductor | |
L1 | Phase L1 | PE | Protective earth conductor | |
L2 | Phase L2 |
Insulation resistance measurement of charger feed-in socket (model 2) (alternating current)
1 | Calibrate insulation resistance tester. |
Observe manufacturers instructions. |
2 | Open socket flap on front bumper. |
3 | Open cover for AC charger feed-in connection (1). |
4 | Adjust insulation resistance tester to resistance test. |
5 | Perform resistance test with insulation resistance tester between protective ground conductor (PE) and attachment point (2) of protective ground conductor (PE) at DC current charge-connection unit for high-voltage battery. |
Specified value < 1 (+0.9) Ω |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
6 | Adjust insulation resistance tester to insulation resistance test and set at 500 V. |
7 | With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between phase L1 (L1) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
8 | With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between phase L2 (L2) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
9 | With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between phase L3 (L3) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
10 | With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between neutral conductor (N) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
S47.70-A045-78
Shown on ECE charger feed-in socket (CCS2) (direct current) |
2 | Attachment point | DC+ | DC current plus connection | |
4 | DC current charge-connection unit feed-in connection | PE | Protective earth conductor | |
DC- | DC current minus connection |
Insulation resistance measurement of charger feed-in socket (CCS2) (direct current)
11 | Calibrate insulation resistance tester. |
Observe manufacturers instructions. |
12 | Open cover for DC current charge-connection unit feed-in connection (4). |
13 | Adjust insulation resistance tester to resistance test. |
14 | Perform resistance test with insulation resistance tester between protective ground conductor (PE) and attachment point (2) of protective ground conductor (PE) at DC current charge-connection unit for high-voltage battery. |
Specified value < 1 (+0.9) Ω |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
15 | Adjust insulation resistance tester to insulation resistance test and set at 500 V. |
16 | With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between minus DC connection (DC-) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
17 | With a test voltage of 500 V at insulation resistance tester, perform insulation resistance test between positive DC connection (DC+) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Check electric line of protective ground conductor (PE) for condition and attachment . |
Then repeat resistance test. |
If specified value is not achieved during repeat test |
|
Replace charger feed-in socket. |
18 | Close socket flap on front bumper. |
Shown on 3-phase high voltage alternating current circuit charging cable (3) |
3 | Charging cable |
L1 | Phase L1 |
L2 | Phase L2 |
L3 | Phase L3 |
N | Neutral conductor |
PE | Protective earth conductor |
P54.10-3957-06
Insulation resistance measurement of 3-phase high voltage alternating current circuit (measuring point is charging cable (3))
19 | Calibrate insulation resistance tester. |
Observe manufacturers instructions. |
20 | Adjust insulation resistance tester to insulation resistance test and set at 500 V. |
21 | With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between phase L1 (L1) and protective ground conductor (PE). |
Specified value > 1 MΩ |
If specified value is not achieved |
|
Replace charging cable (3). |
22 | With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between phase L2 (L2) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Replace charging cable (3). |
23 | With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between phase L3 (L3) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Replace charging cable (3). |
24 | With a test voltage of 500 V at insulation resistance meter, perform insulation resistance measurement at one of the two connectors of charging cable (3) between neutral conductor (N) and protective ground conductor (PE). |
Specified value > 1 MΩ. |
If specified value is not achieved |
|
Replace charging cable (3). |