P46.50-2038-06
1 Rotary valve and control bush housing
3 Screw
10 Rack-and-pinion steering
Y10 Direct steering solenoid valve
| Remove/install | ||
Danger! | Risk of injury to skin or eyes caused by hydraulic fluid spraying out under high pressure. Risk of poisoning caused by swallowing hydraulic fluid | Depressurize the hydraulic system completely before starting any work on the system. Wear protective clothing and safety glasses. | |
1 | Remove bolts (3) from rotary valve and control bushing housing (1) and remove the direct steering solenoid valve (Y10) from the rack-and pinion steering (10) | The area surrounding the separation point should be cleaned thoroughly before opening the hydraulic system. Even the smallest dirt particles, introduced into the hydraulic components, can lead to malfunctions and a total failure of the hydraulic system. | |
Installation: Replace bolts (3) and sealing ring on direct steering solenoid valve (Y10). Ensure that the sealing ring is correctly seated. | |||
| |||
2 | Install in the reverse order | ||
3 | Connect Star Diagnosis and check parameter function |