P43.05-A007-09
1 | Electrical connector | 4 | Screw | |
2 | Electric line | M56 | Electric vacuum pump | |
3 | Vacuum line |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
| Remove/install | ||
1 | Remove engine compartment linings. | ||
2 | Release electrical connector(1) and disconnect. | ||
3 | Expose electrical line (2). | ||
4 | Remove vacuum line (3) from electric vacuum pump (M56) and seal with suitable stop plugs. | Record plug | |
5 | Expose vacuum line (3). | ||
6 | Remove screws/bolts (4). | Screw, vacuum pump to front axle drive module | |
7 | Remove electric vacuum pump (M56) upward. | ||
8 | Install in the reverse order. |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ar6120p1105eq
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne