Measurement of angle 4 on rear axle differential (3)
An angle that has already been measured can be measured a second time if required. To do so, with the Measurement menu displayed, press the "STEP" button repeatedly until the display indicates Ready to measure the relevant angle.
1 | Mount sensor holder (020c) centrally onto sensor (020a). |
P41.10-2064-01
2 | Clean dirt as well as paint and sealant residue from contact surfaces of adapter (020h) on housing of rear axle differential (3). |
Remove any unevenness on surface of material using a suitable tool. |
3 | Fit sensor (020a) with magnetic sensor mount (020c) onto magnetic adapter (020h) by turning slightly. |
When each measurement is taken, the side of the sensor (020a) at which the spiral cable (020b) is connected must point in the direction of travel. |
4 | Place and hold measuring instrument with magnetic adapter (020h) and sensor (020a) on the housing of rear axle differential (3). |
Aid of helper required. |
5 | Align strut fitted with spirit level (020i) so that it is horizontal, and tighten screws/bolts (020k). |
Aid of helper required. |
Example illustration |
P41.10-2397-06
The meter is ready to take a measurement. The value measured is shown on the display.
6 | Press "SAVE" button. |
The device saves the values. |
Measurement value display message angle piece 4: Display, e.g. 2.68° |
P41.10-2082-01
A confirmation message appears briefly and then the meter indicates that it is ready to measure the next angle. The measurement is completed and stored in memory.
Display message confirmation |
P41.10-2076-01
7 | Remove measuring instrument with magnetic adapter (020h) and sensor (020a). |
8 | Protect contact surfaces of adapter (020h) on housing of rear axle differential (3) against corrosion. |