ar4110p008501msa

Measure absolute angle at transmission

Typ ar · temat 41.10 · wersja 0100 · 2018-03-29

Dotyczy: Model 257

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 2 Podwozie › 41 Wał napędowy › 41.10 Wał napędowy — Seria 257

EinPAS 17 Zespół przeniesienia napędu/ oś › 17.40 Wał napędowy › 17.40.30 Wał napędowy napędu/ napędu na cztery koła — Seria 257

AR41.10-P-0085-01MSA

Measure absolute angle at transmission

Notes on measuring the drive shaft articulation angle

AH41.10-P-0002-01LF

000 588 04 19 00 Articulation angle inclinometer

WS26.00-P-0140B

Model

257

Measure absolute angle at transmission

Electronic inclination / propeller shaft articulation angle meter

1

Press the STEP button.


Articulation angle measurement is selected.


Display message menu

P41.10-2070-01

Measure absolute angle at transmission

2

Press STEP button while main menu is displayed.


Measurement is selected.


The measurement of all angles should be carried out without interruption. An angle that has already been measured can be measured a second time if required. To do so, with the Measurement menu displayed, press the STEP button repeatedly until the display indicates Ready to measure the relevant angle.


Display message main menu

P41.10-2071-01

Measure absolute angle at transmission

Example illustration

3

Clean mounting hole and surrounding area in transmission housing.



4

Select suitable measuring sleeve mount (020e) for mounting hole.



5

Insert measuring sleeve mount (020e) into mounting hole.



6

Turn threaded pin (020f) to left and tighten.


P41.10-2441-01

Measure absolute angle at transmission

7

Screw measuring sleeve (020g) onto measuring sleeve mount (020e) and tighten all the way up to underside of transmission by hand.


The entire contact surface of the measuring sleeve (020g) must lie flat against the underside of transmission.


Example illustration

P41.10-2442-01

Measure absolute angle at transmission

8

Attach sensor holder (020c) with both screws centrally on sensor (020a).


P41.10-2064-01

Measure absolute angle at transmission

9

Fit sensor (020a) with magnetic sensor mount (020c) on measuring sleeve (020g) by turning slightly.


When each measurement is taken, the side of the sensor (020a) at which the spiral cable (020b) is connected must point in the direction of travel.
Otherwise measurement errors can occur.


The device is ready to take a measurement and the measured values are shown in the display.


Example illustration

P41.10-2443-01

Measure absolute angle at transmission

10

Press SAVE button.


The values are saved.


Measurement values on display message for angle piece 1: Display, e.g. 1.92°

P41.10-2075-01

Measure absolute angle at transmission

A confirmation message appears briefly.

Display message confirmation

P41.10-2076-01

Measure absolute angle at transmission

The display then indicates that the device is ready for the next measurement (angle 2).

P41.10-2077-01

Measure absolute angle at transmission

11

Remove sensor (020a) and sensor holder (020c) from measuring sleeve (020g).



12

Remove sensor holder (020c) from sensor (020a).



13

Unscrew measuring sleeve (020g) from measuring sleeve mount (020e).


Example illustration

P41.10-2443-01

Measure absolute angle at transmission

14

Release threaded pin (020f) and remove measuring sleeve mount (020e) from mounting hole.


Example illustration

P41.10-2441-01

Powiązane dokumenty