P22.10-A034-09
1 | Front axle major assembly carrier | 5 | Retaining plate | |
2 | Nuts | 6 | Nut | |
3 | Bolts | 7 | Screw | |
4 | Bolts | 8 | Bearing at rear |
Shown in removed condition |
8 | Bearing at rear |
P22.10-A035-11
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Notes on bolted connections with self tapping screws | ||
| Remove | ||
1 | Remove voltage of high-voltage on-board electrical system. | ||
2 | Remove high-voltage battery | ||
3 | Support the front axle major assembly carrier (1) with a hydraulic lift in a suitable place. | Place the hydraulic lift as close as possible to the retaining plate (5). | |
4 | Remove nuts (2). | ||
5 | Remove screw/bolts (3). | ||
6 | Unscrew screws (4) and remove retaining plate (5) | ||
7 | Remove nut (6). | ||
8 | Remove screws (7d) and remove bearing at rear (8). | ||
| Install | ||
9 | Position a new bearing at rear (8) in the front axle major assembly carrier (1) and screw in the screws (7). | Screw, rear bearing to front axle major assembly carrier | |
10 | Attach nut (6) | Nut, rear bearing to transmission tunnel reinforcement | |
11 | Place retaining plate (5) in position and screw in the screws (4). | Screw, retaining plate to main floor | |
12 | Screw in screws (3). | Bolt, retaining plate to bearing at rear | |
13 | Install nuts (2). | Nut, transmission tunnel strut to retaining plate | |
14 | Remove the hydraulic lift. | ||
15 | Install high-voltage battery |
Powiązane dokumenty
- ah0000p000701sf Wskazówki dotyczące połączeń śrubowych z samonacinającymi śrubami
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ar4770p0002eq
- ar4770p1000eq
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne