S15.40-4001-06
1 Screw
2 Cover
3 Retaining clips
4 Bolt (regulator)
5 Governor
6 Ground cable
B+ Connection
D+ Connection
G1 Generator
| Remove/install | ||
| Notes on battery | ||
1 | Disconnect ground lead from battery | Installation: Code radio. | |
2 | Unscrew nut at connection (D+) on alternator (G1) | | |
3 | Unscrew nut at connection (B+) on alternator (G1) | Installation: Mount the protective cap. | |
| |||
4 | Unscrew bolts (1) | ||
5 | Release retaining clamp (3) | ||
6 | Remove cap (2) | ||
7 | Unscrew bolts (4) | ||
8 | Remove regulator (5) | ||
9 | Install in the reverse order | Installation: When inserting regulator (5), ensure that the ground cable (6) is making contact with the regulator (5). |