1 | Ignition cable plug |
2 | Ignition coil |
3 | Connector |
4 | Screw |
S15.12-2500-06
| Remove/install | ||
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
1 | Disconnect ground line from battery | ||
2 | Unplug ignition cable plug (1) from the ignition coil (2) | | |
3 | Unplug plug (3) from the ignition coil (2) | ||
4 | Unscrew screws (4) | Bolt, ignition coil to the upper timing case cover | |
5 | Remove ignition coil (2) | ||
6 | Install in the reverse order | ||
| Check | ||
7 | Check with the HHT fault memory and clear if necessary |
Powiązane dokumenty
- ar5410s0005a
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne