S14.20-4547-09
1 | Screw/bolt | 4 | Electrical connection | 7 | Prying off thread | ||
2 | Bracket | 5 | Electrical connection | Y27/20 | High-pressure exhaust gas recirculation actuator | ||
3 | Screw/bolt | 6 | Screw/bolt |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove air filter housing | ||
2 | Remove screw/bolt (1) | ||
3 | Remove bracket (2) | Remove screw/bolt (3) to do this. | |
4 | Disconnect electrical connection (4) | ||
5 | Disconnect electrical connection (5) | ||
6 | Remove screw/bolts (6) | Bolt, high-pressure exhaust gas recirculation valve to charge air distributor | |
7 | Turn high pressure exhaust gas recirculation actuator (Y27/20) | The prying off thread (7) must be accessible. | |
8 | Remove high pressure exhaust gas recirculation actuator (Y27/20) | | |
Installation: Replace seal. | |||
9 | Install in the reverse order |