S08.40-A002-79
Shown with engine 780.701 |
1 | Park pawl sensor | 4 | O-ring | |
2 | Electrical connector | 5 | Axle drive module | |
3 | Screw |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Caution | Risk of injury to skin and eyes due to handling of transmission oil. Health risk caused by swallowing transmission oil | Wear protective gloves, protective clothing and safety glasses. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m). | ||
2 | Remove bottom engine compartment paneling. |
| |
3 | Release and disconnect the electrical connector (2). | ||
4 | Remove screw (3) . | ||
5 | Pull park pawl sensor (1) out of axle drive module (5) and remove. | ||
| Transmission oils (specification 236.24) | ||
Installation: Coat O-ring (4) of park pawl sensor (1) with transmission oil. | |||
| Check | ||
6 | Check O-ring (4) of park pawl sensor (1) for damage. | If damage is detected | |
| |||
Replace park pawl sensor (1). | |||
7 | Install in the reverse order. | ||
8 | Perform teach-in routine for park pawl sensor (1) with diagnostic device. | When replacing park pawl sensor (1). | |
|
Powiązane dokumenty
- ad0000s200004e
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ar6120s1105e
- ar6120s1105e
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne
- as0040z000101a Niebezpieczeństwo obrażeń skóry i oczu podczas kontaktu z olejem przekładniowym. Zagrożenie dla zdrowia na skutek połknięcia oleju przekładniowego
- bb0040p023624a