B63 | Intake air temperature sensor |
1 | Clutch |
S07.52-1005-06
| Remove/install | ||
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
1 | Disconnect ground line of battery | ||
2 | Remove intake air temperature sensor (B63) | To do so, press together and remove retaining clamps | |
3 | Remove coupling (1) of intake air temperature sensor | ||
4 | Check O-ring (arrow) | Replace if damaged | |
5 | Install in the reverse order | ||
6 | Read out PEC control unit fault memory; clear if necessary | DMAN engine |
Powiązane dokumenty
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne