D07.07-1121-08
Shown on model 907 with engine 651 |
1 | Hot film mass air flow sensor | 2 | Electrical connector | 3 | Bolts |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Disconnect electrical connection (2). | ||
2 | Remove air intake pipe from hot film mass air flow sensor (1). | To do this loosen clamp. | |
Installation: Check clamp for damage. | |||
Clamp, air intake pipe to hot film mass air flow sensor | |||
Depending on the findings, | |||
| |||
Replace damaged clamp. | |||
3 | Remove hot film mass air flow sensor (1). | To do this, remove screws/bolts (3). | |
Installation: Wet sealing ring with lubricant. Check sealing ring. | |||
Special lubricant | |||
Depending on the findings, | |||
| |||
Replace sealing ring. | |||
4 | Install in the reverse order. | ||
5 | Initialize hot film mass air flow sensor (1). | When replacing the hot film mass air flow sensor (1). | |
| Connect/disconnect diagnostic unit |
Powiązane dokumenty
- ad0000d200006ts
- ah0000p500001a Wskazówki dotyczące zapobiegania uszkodzeniom na skutek zabrudzeń i ciał obcych
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego