P07.04-2979-09
Shown on model 177 |
1 | Electrical connector | 3 | Screw | B28/8 | Differential pressure sensor (DPF) | ||
2 | Hoses |
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on safety-relevant components | |||
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmitter range (min. 2 m). | ||
2 | Release and disconnect electrical connector (1) from DPF differential pressure sensor (B28/8). | ||
3 | Release clamps of hoses (2) of DPF differential pressure sensor (B28/8) at steel lines of diesel particulate filter. | | |
4 | Remove hoses (2) from steel lines of diesel particulate filter. | ||
5 | Remove screw (3) and remove DPF differential pressure sensor (B28/8). | Bolt, differential pressure sensor to bracket | |
6 | Remove hoses (2) from DPF differential pressure sensor (B28/8). | When replacing hoses (2). | |
7 | Install in the reverse order. | ||
8 | Connect vehicle diagnosis system, read out fault memory and clear if necessary. | ||
|
Powiązane dokumenty
- ad0000p200006mfa
- ah0000p500001a Wskazówki dotyczące zapobiegania uszkodzeniom na skutek zabrudzeń i ciał obcych
- ah0000z001901a Wskazówki dotyczące elementów wpływających na bezpieczeństwo
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- as0000z000201a Niebezpieczeństwo zranienia skóry i oczy na skutek kontaktu z gorącymi lub żarzącymi się przedmiotami