S07.50-2501-06
1 Intake manifold
2 Connector
3 Bolt
4 Injection nozzle holder
5 Injection nozzle
6 Seals
7 Gasket
| Removing, installing | ||
Danger! | Risk of explosion from ignition. Risk of poisoning from inhaling and swallowing fuel. Risk of injury as a result of fuel coming into contact with skin and eyes. | No fire, naked flame or smoking. Pour fuels only into suitable and appropriately marked containers. Wear protective clothing when handling fuel. | |
1 | Remove intake manifold (1) | ||
2 | Unplug connector (2) of injection nozzles | ||
3 | Take off bolts (3) attaching injection nozzle holder (4) at intake manifold (1) | | |
4 | Take off injection nozzle holder (4) | Do not damage injection nozzles (5). | |
5 | Take injection nozzles (5) out of injection nozzle holder | Installation: replace seals (6). | |
6 | Install in the reverse order | ||
| Inspecting | ||
7 | Inspect injection nozzles (5) for leaks |