001 589 76 21 00
Compression tester
220 589 05 99 00
Electrical connection kit
Connecting |
S01.10-4652-77
1 | Remove cover (1). |
2 | Remove cover (2). |
3 | Connect connection line of compression pressure recorder to electricity distributor (3). |
4 | Release cover of housing for fuse and relay module (7) (arrows) and remove it. |
5 | Release relay socket (5) and push it downwards. |
6 | Lift relay socket (5) until fuse (5.1) is accessible. |
7 | Actuate fuse (5.1) and remove starter circuit 50 relay (4) out of relay socket (5). |
8 | Connect compression pressure recorder to circuit 87 slot (6) using adapter line from electrical connection kit. |
9 | Disconnect in reverse order. |
S01.10-4654-81