Commercially available tools
Number | Designation | |
WH58.30-Z-1003-05A | Connecting pieces or connection pieces for compressed air testers, Firma Bosch | |
WH58.30-Z-1015-05A | Cylinder leakage testing unit |
S01.00-2001-01
1 Screw the connection element (1), which corresponds to the straight or elbowed connection element (2), into the prechamber of the cylinder to be tested.
2 Take the cylinder watertightness tester and screw tube (3) into tester (2)
Pay attention to the handling instructions