P15.18-2002-09
1 Protective sleeve
N14 Preglow time relay
W11/5 Engine / body ground strap
X4/30 Circuit 30 terminal block
X15/2 100 °C temperature switch connector
X26/2 Engine separation point connector
X85/1 AC harness / engine harness connector
| Removing, installing | ||
1 | Pull protective sleeve (1) off plug connections of engine separation point | Left of firewall in engine compartment Installation: Seal protective sleeve with cable strap | |
2 | Separate plug connections of engine separation point (X26/2) | Green and white connectors. | |
3 | Separate plug connection of 100 °C temperature switch (X15/2) | ||
4 | Separate plug connection of AC wiring harness/ engine wiring harness (X85/1) | If AC (H02) fitted. | |
5 | Separate terminal block of engine circuit 30 (X4/30) | Only black power cable. | |
6 | Unplug connector of preglow time relay (N14) | ||
7 | Detach connection of circuit 30 at generator | | |
8 | Detach connection of circuit 61 at generator | | |
9 | Detach ground strap of engine/body (W11/5) at frame | ||
10 | Install in the reverse order |
Generator