001 589 78 09 00
Socket wrench
611 589 02 63 00
Intermediate piece
611 589 01 63 00
Female connector
1 | Remove check valve from the screw-in piece (1). |
2 | Screw in screw-in fitting (1) using the socket set into glow plug bore. |
3 | Attach intermediate piece (2) to screw-in fitting (1). |
4 | Fit connection piece (3) to intermediate piece (2). |
D01.00-1118-06
5 | Connect cylinder leakage testing unit (4) to connection piece (3). |
Observe operating instructions from manufacturer of cylinder leakage tester (4). Calibrate cylinder leakage testing unit (4) according to the manufacturer's instructions. |