Stationary heater (STH) diagnosis, fault memory

Typ ad · temat 83.70 · wersja 0101 · 2003-06-13

Dotyczy: MODEL 129 as of 1.6.97 with CODE (228) stationary heater

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.70 Ogrzewanie w czasie postoju, dodatkowe, nagrzewnica dodatkowa — Seria 129

AD83.70-P-4002A

Stationary heater (STH) diagnosis, fault memory

12.8.97

MODEL 129 as of 1.6.97 with CODE (228) stationary heater

Stationary heater (STH) diagnosis, advanced information

AD83.70-P-2001A

Connection and use of test equipment

AD00.00-P-1000AZ

Connect Hand-Held Tester (HHT) and read out fault memory

AD00.00-P-2000-03A

Notes on diagnosis with Hand-Held Tester (HHT) on heater booster/stationary heater

AD83.70-P-2001-02A

If a fault is displayed, check fuses, cables, plugs and connectors in accordance with the relevant electric wiring diagram for open-circuit and correct connection.

Fault memory

Fault code

Possible cause

Note

Remedy

No fault code

No fault recognized

If there is a complaint nevertheless:

Stationary heater (STH) diagnosis, troubleshooting

AD83.70-P-5001A

Stationary heater/heater booster control module (A6n1) defective

Replace stationary heater/heater booster control module (A6n1)

No flame at the start of heater operation nor after automatic repeat start.

See HHT

Flame goes out during heater operation without a new flame after automatic attempt at starting

Flame goes out more than four times during a heater boost cycle

See HHT

See HHT

Overvoltage

Undervoltage

Operating voltage has exceeded 15.5 V for more than 6 seconds

Operating voltage has been below 10.2 V for more than 20 seconds

AD83.70-P-6001-01A

AD83.70-P-6001-01A

On flame monitor interrogation, the glow pin (A6r2) in its flame monitor function reports a flame prior to the preglow phase.

Replace glow pin (A6r2)

|— —|+

— / / —, |— —| –

Glow pin (A6r2) circuit, short-circuit to positive

Glow pin (A6r2) circuit, open-circuit or short-circuit to ground

AD83.70-P-6001-04A

AD83.70-P-6001-04B

Malfunction lock-out exists:

Thermal fuse in stationary heater/heater booster unit (A6) has blown because the coolant in the heater unit has exceeded the maximum permissible temperature of 125°C

or

3 different or the same faults have occurred in sequence

See HHT

|— —| –

— / / —, |— —|+

Stationary heater fuel metering pump (Y23) circuit, short-circuit to ground

Stationary heater fuel metering pump (Y23) circuit, open-circuit or short-circuit to positive

AD83.70-P-6001-05A

AD83.70-P-6001-05B

Overload, |— —|

— / / —

Combustion air blower (A6m2), overload or short-circuit

Combustion air blower (A6m2), open-circuit

AD83.70-P-6001-06A

AD83.70-P-6001-06B

Overload, |— —|

— / / —

Circulating pump (A6m1), overload or short-circuit

Circulating pump (A6m1), open-circuit

AD83.70-P-6001-07A

AD83.70-P-6001-07B

|— —| –

Cable to climate control module, short-circuit to ground

AD83.70-P-6001-08A