AD80.20-P-8003A | Retractable rear head restraints (RHR), testing pneumatics | 7.3.97 |
MODEL 140 as of 1.6.97
| Permissible leakage in complete system at vacuum of 300 mbar in 1 minute: | Pneumatics testing 30 mbar | |
Permissible leakage of actuators with lines at vacuum of 300 mbar in 1 minute: |
25 mbar | ||
| If an actuator is not working properly, even though no leakage is detected, check line concerned for kinks and blockage | ||
Connection and use of test equipment | |||
Retractable rear head restraints (RHR), diagnosis, advanced information | |||
Diagnostic tools, RHR | |||
Retractable rear head restraints (RHR), pneumatics, location of components | |||
| Testing | ||
1 | Complete system, testing pneumatics, RHR | 1. Disconnect pneumatic line for retractable rear head restraints, rear/RHR connection or RTR/RHR connection on pneumatic system equipment. 2. Connect tester with plug 202 805 03 44 to socket which was disconnected. 3. Disconnect remote trunk release pneumatic line at T-piece and seal T-piece Parts for testing: Plug 202 805 03 44 Rubber hose, 50 mm 007 997 61 82 Pneumatic line, 1 m 000 158 14 35 Rubber cap 000 987 11 45 | |
2 | Actuators, testing pneumatics, RHR | 1. Remove retractable head restraints actuator 2. Connect tester for vacuum and pressure systems to actuator pneumatic connection. Parts for testing: Rubber hose, 50 mm 007 997 61 82 Pneumatic line, 1 m 000 158 14 35 Socket 202 805 02 53 | |
3 | Line, testing pneumatics, RHR | Connect tester to one end of pneumatic line with plug part no. 202 805 03 44 and seal other ends with sealing plug part no. 124 805 02 44 Parts for testing: Plug 202 805 03 44 Sealing plug 124 805 02 44 Rubber hose, 50 mm 007 997 61 82 |
Powiązane dokumenty
- ad0000p1000az Podłączanie i zastosowanie narzędzi diagnostycznych
- ad8020p200301a
- ad8020p2003a
- ad8020p800301a Cały układ, test układu pneumatycznego KAF
- ad8020p800302a Elementy, test układu pneumatycznego KAF
- ad8020p800303a Przewody, test układu pneumatycznego KAF
- gf9116p000103a