AD80.20-P-6001-01A | Interior switch (CL), testing electrical system, CL | Model 170 |
| Scope of test | Measuring instrument/ | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Interior switch (CL) (S6/1s2) Model 170 | N10-3 49 (C) |
|
| Disconnect multi-function control module (N10-3) from . S6/1s2: Not actuated Lock: Press and hold down Unlock: Press and hold down |
>20 kΩ approx. 200 Ω <1 Ω | Cables S6/1s2 |