AD07.61-P-6000-44B | Oxygen sensor signal downstream of TWC - Check ME-SFI gasoline injection system electrics | |
| Scope of test | Tester/test connection | Operation/ prerequisite | Specified value | Possible cause/ remedy | ||
1.0 | Oxygen sensor on left downstream of TWC (G3/5) or on right downstream of TWC (G3/6) Oxygen sensor signal |
40 (1.40) | N3/11 N3/12 |
42 (1.42) | At coolant temperature > 80 °C, start engine and maintain engine speed of 2000-3000 rpm for approx. 2 minutes Engine: at idle speed | Negative or positive deviation from range between 450 to 500 mV must occur once within one minute | Lead |