be8330p100002a

Additional fan

Type be · emne 83.30 · versjon 0102 · 2013-03-19

Gjelder for: MODEL 129, 140, 202

Ikke tilgjengelig på «no»; vises på Engelsk.

Plassering

Funksjonsgruppe 3 Påbygg › 83 Klimatisering › 83.30 Klimaanlegg — Serie 129 · Serie 140 · Serie 202

EinPAS 15 Motor › 15.25 Motorkjølesystem › 15.25.45 Vifte/vifteclutch/viftemotor — Serie 129 · Serie 140 · Serie 202

BE83.30-P-1000-02A

Additional fan

MODEL

129, 140, 202

Check values for additional fan

Number

Designation

MODEL 140.### 1A up to 123445
with refrigerant pressure sensor

MODEL 140.### 1A as of 123446
with refrigerant pressure sensor

BE83.30-P-1001-02A

Additional fan pressure switch

Cut-in pressure

Overpressure

bar

–

–

Switch-off pressure

Overpressure

bar

–

–

BE83.30-P-1002-02A

Shift points for additional fan, cut-in pressure

Stage 1

Overpressure

bar

14

16

Stage 2

Overpressure

bar

17

20

Stage 3

Overpressure

bar

20

–

BE83.30-P-1003-02A

Shift points for additional fan, cut-out pressure

Stage 1

Overpressure

bar

12

13

Stage 2

Overpressure

bar

14

17

Stage 3

Overpressure

bar

17

–

Check values for additional fan

Number

Designation

MODEL 202

MODEL 129

BE83.30-P-1001-02A

Additional fan pressure switch

Cut-in pressure

Overpressure

bar

–

19,5...20,5

Switch-off pressure

Overpressure

bar

–

14,5...15,5

BE83.30-P-1002-02A

Shift points for additional fan, cut-in pressure

Stage 1

Overpressure

bar

16

–

Stage 2

Overpressure

bar

20

–

Stage 3

Overpressure

bar

–

–

BE83.30-P-1003-02A

Shift points for additional fan, cut-out pressure

Stage 1

Overpressure

bar

13

–

Stage 2

Overpressure

bar

17

–

Stage 3

Overpressure

bar

–

–