be8330p100001a

Air conditioning system temperature sensor

Type be · emne 83.30 · versjon 0200 · 2018-10-16

Gjelder for: Model 129, 140, 202

Ikke tilgjengelig på «no»; vises på Engelsk.

Plassering

Funksjonsgruppe 3 Påbygg › 83 Klimatisering › 83.30 Klimaanlegg — Serie 129 · Serie 140 · Serie 202

EinPAS 39 Varme/ventilasjon/kjøling › 39.15 Klimaregulering › 39.15.12 Sensor/bryter/ledningsnett — Serie 129 · Serie 140 · Serie 202

BE83.30-P-1000-01A

Air conditioning system temperature sensor

Model

129, 140, 202

Modification notes

26.09.2018

Value changed:Evaporator temperature sensor resistance value, at ambient temperature

26.09.2018

Value changed:Outside air temperature sensor, resistance value at ambient temperature

Air conditioning system temperature sensor check values

Number

Designation

Model 129

Model 140

BE83.30-P-1001-01A

Evaporator temperature sensor resistance value, at ambient temperature

0 °C

kΩ

8,1...9,9

8,1...9,9

5 °C

kΩ

6,3...7,7

6,3...7,7

10 °C

kΩ

5,0...6,0

5,0...6,0

15 °C

kΩ

4,0...4,6

4,0...4,6

20 °C

kΩ

3,1...3,9

3,1...3,9

25 °C

kΩ

2,4...3,0

2,4...3,0

30 °C

kΩ

1,9...2,3

1,9...2,3

35 °C

kΩ

1,6...2,0

1,6...2,0

40 °C

kΩ

1,4...1,6

1,4...1,6

BE83.30-P-1002-01A

Outside air temperature sensor, resistance value at ambient temperature

15 °C

kΩ

4,0...6,0

4,0...6,0

20 °C

kΩ

3,1...3,9

3,1...3,9

25 °C

kΩ

2,4...3,0

2,4...3,0

30 °C

kΩ

1,9...2,3

1,9...2,3

35 °C

kΩ

1,6...2,0

1,6...2,0

40 °C

kΩ

1,4...1,6

1,4...1,6

45°C

kΩ

1,1...1,3

1,1...1,3

Air conditioning system temperature sensor check values

Number

Designation

Model 202

BE83.30-P-1001-01A

Evaporator temperature sensor resistance value, at ambient temperature

0 °C

kΩ

8,1...9,9

5 °C

kΩ

6,3...7,7

10 °C

kΩ

5,0...6,0

15 °C

kΩ

4,0...4,6

20 °C

kΩ

3,1...3,9

25 °C

kΩ

2,4...3,0

30 °C

kΩ

1,9...2,3

35 °C

kΩ

1,6...2,0

40 °C

kΩ

1,4...1,6

BE83.30-P-1002-01A

Outside air temperature sensor, resistance value at ambient temperature

15 °C

kΩ

4,0...6,0

20 °C

kΩ

3,1...3,9

25 °C

kΩ

2,4...3,0

30 °C

kΩ

1,9...2,3

35 °C

kΩ

1,6...2,0

40 °C

kΩ

1,4...1,6

45°C

kΩ

1,1...1,3