Geldig voor: MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H62) Warm air heater "Eberspächer D3 LP" MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H62) Warm air heater "Eberspächer D3 LP" MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP'

Niet beschikbaar in “nl”; getoond in Engels.

Plaats

Functiegroep 3 Opbouw/carrosserie › 83 Temperatuurregeling › 83.70 Standverwarming, extra verwarming — Serie 940 (modellen 899) · Serie 942 (modellen 899) · Serie 950 · Serie 952 · Serie 953 · Serie 954 · Serie 970 · Serie 972 · Serie 974 · Serie 975 · Serie 976

EinPAS 39 Verwarming/ventilatie/koeling › 39.25 Interieurvoorverwarming/standverwarming/extra verwarming › 39.25.30 Verwarmingseenheid — Serie 940 (modellen 899) · Serie 942 (modellen 899) · Serie 950 · Serie 952 · Serie 953 · Serie 954 · Serie 970 · Serie 972 · Serie 974 · Serie 975 · Serie 976

AR83.70-W-5758A

Removing and installing glow plug

2.2.98

MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H62) Warm air heater "Eberspächer D3 LP"

MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H62) Warm air heater "Eberspächer D3 LP"

MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP

Removing and installing glow plug

W83.70-0048-06

1 Hex. screw
2 Cover
3 Glow plug
4 Gasket
5 Glow plug screen

Removal, installation

1

Disconnect ground lead from battery

Do not interrupt main battery supply while heater is in operation or during heater shut-off delay.

2

Remove cover (2)

3

Unscrew connection cable from glow plug

4

Remove glow plug (3)

Installation: Replace gasket (4).

5

Remove glow plug screen (5)

Installation: Observe position of lug (arrow A) on glow plug screen. The hole (arrow B) for glow plug ventilation must be free.

6

Reinstall in opposite order

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation.

Do not start up or operate stationary heaters, auxiliary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

7

Check stationary heater for proper function

AR83.70-W-5302-02C