ar8370d5807f

Remove and install combustion and heater air blower

Type ar · thema 83.70 · versie 0101 · 2003-09-29

Geldig voor: MODELS 901.62#, 902.62#, 903.62#, 904.62#, 905.62# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater AIRTRONIC heater D2 MODELS 901.66# /67#, 902.66# /67#, 903.66# /67#, 904.66# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater AIRTRONIC heater D4 MODELS WD1##, WD2##, WD3##, WD6##, WD7## ### as of 382002 as of 3/12/02 with CODE (H11) Warm air auxiliary heater AIRTRONIC heater D4

Niet beschikbaar in “nl”; getoond in Engels.

Plaats

Functiegroep 3 Opbouw/carrosserie › 83 Temperatuurregeling › 83.70 Standverwarming, extra verwarming — Serie 901 (modellen 62*, 66*, 67*) · Serie 902 (modellen 62*, 66*, 67*) · Serie 903 (modellen 62*, 66*, 67*) · Serie 904 (modellen 62*, 66*) · Serie 905 (modellen 62*)

EinPAS 39 Verwarming/ventilatie/koeling › 39.25 Interieurvoorverwarming/standverwarming/extra verwarming › 39.25.30 Verwarmingseenheid — Serie 901 (modellen 62*, 66*, 67*) · Serie 902 (modellen 62*, 66*, 67*) · Serie 903 (modellen 62*, 66*, 67*) · Serie 904 (modellen 62*, 66*) · Serie 905 (modellen 62*)

AR83.70-D-5807F

Remove and install combustion and heater air blower

26.11.02

MODELS 901.62#, 902.62#, 903.62#, 904.62#, 905.62# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
AIRTRONIC heater D2

MODELS 901.66# /67#, 902.66# /67#, 903.66# /67#, 904.66# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
AIRTRONIC heater D4

MODELS WD1##, WD2##, WD3##, WD6##, WD7## ### as of 382002 as of 3/12/02 with CODE (H11) Warm air auxiliary heater
AIRTRONIC heater D4

Remove and install combustion and heater air blower

D83.70-1292-06

1 Cover

2 Auxiliary heating control unit

3 Heat exchanger with combustor

4 Casing housing

5 Flange gasket

6 Seal

7 Combustion and heater air blower

8 Locking lug

A-D tightening sequence

Remove/Install

1

Remove heater

Models 901.6, 902.6, 903.6, 904.6, 905.6 with AIRTRONIC heater D2

AR83.70-D-5302H

Models 901.6, 902.6, 903.6, 904.6,

WD1, WD2, WD3, WD6, WD7 with AIRTRONIC heater D4

AR83.70-D-5302K

2.1

Remove heater from the housing

Models 901.6, 902.6, 903.6, 904.6,

WD1, WD2, WD3, WD6, WD7 with AIRTRONIC heater D4

AR83.70-D-5399A

3

Unlock locking lugs (8) of cover (1)

4

Lift up cover (1) and remove from casing housing (4) of the heater

5.1

Detach exhaust gas line, combustion air line, flange plate and flange gasket from heater unit

Only AIRTRONIC heater D2.

Installation: Check condition of flange gasket (5) and replace if necessary.

6

Remove auxiliary heater control unit (2)

AR83.70-D-5937F

7

Take heater out of casing housing

8

Detach combustion air blower and hot air blower (7) from heat exchanger (3)

Installation: Note the tightening sequence A-D for the screws.

9

Take off gasket (6)

Installation: Clean sealing surfaces. Replace gasket (6).

10

Install in the reverse order