ar8370d5653d

Remove/install fuel strainer in intake connection fittings of fuel metering pump

Type ar · thema 83.70 · versie 0107 · 2003-09-16

Geldig voor: MODEL 690.6 with CODE (H12) Hot water auxiliary heater MODEL 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H12) Hot water auxiliary heater MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (H12) Hot water auxiliary heater MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HZ9) Heater booster, diesel engine MODEL 901.6, 902.6, 903.6, 904.6 with CODE (HZ5) Warm air auxiliary heater 10 kW with timer MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (H12) Hot water auxiliary heater MODE

Niet beschikbaar in “nl”; getoond in Engels.

Plaats

Functiegroep 3 Opbouw/carrosserie › 83 Temperatuurregeling › 83.70 Standverwarming, extra verwarming — Serie 690 (modellen 6**) · Serie 901 (modellen 0**, 3**, 4**, 6**) · Serie 902 (modellen 0**, 3**, 4**, 6**) · Serie 903 (modellen 0**, 3**, 4**, 6**) · Serie 904 (modellen 0**, 3**, 4**, 6**) · Serie 905 (modellen 6**)

EinPAS 39 Verwarming/ventilatie/koeling › 39.25 Interieurvoorverwarming/standverwarming/extra verwarming › 39.25.46 Pomp/reservoir — Serie 690 (modellen 6**) · Serie 901 (modellen 0**, 3**, 4**, 6**) · Serie 902 (modellen 0**, 3**, 4**, 6**) · Serie 903 (modellen 0**, 3**, 4**, 6**) · Serie 904 (modellen 0**, 3**, 4**, 6**) · Serie 905 (modellen 6**)

AR83.70-D-5653D

Remove/install fuel strainer in intake connection fittings of fuel metering pump

18.4.97

MODEL 690.6 with CODE (H12) Hot water auxiliary heater

MODEL 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H12) Hot water auxiliary heater

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (H12) Hot water auxiliary heater

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HZ9) Heater booster, diesel engine

MODEL 901.6, 902.6, 903.6, 904.6 with CODE (HZ5) Warm air auxiliary heater 10 kW with timer

MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (H12) Hot water auxiliary heater

MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (HZ9) Heater booster, diesel engine

MODEL YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (H12) Hot water auxiliary heater

MODEL YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (HZ9) Heater booster, diesel engine

MODEL WD1, WD2, WD3, WD6, WD7 with CODE (H12) Hot water auxiliary heater

MODEL WD1, WD2, WD3, WD6, WD7 with CODE (HZ9) Heater booster, diesel engine

Remove/install fuel strainer in intake connection fittings of fuel metering pump

D83.70-1274-06

1 Union nut

2 Hose clamp

3 Tank fuel line

4 Fuel strainer

Remove/Install

Danger!

Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel.

No fire, sparks, naked flames or smoking.
Pour fuels only into suitable and appropriately marked containers.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

1

Loosen hose clamp (2)

2

Detach tank fuel line (3)

Collect fuel which flows out.

3

Unscrew union nut (1)

To release the union nut counterhold the fuel metering pump.

4

Remove the fuel strainer (4)

5

Install in the reverse order