ar4020d032203c
Check caster and assign to tabular value
Type ar · thema 40.20 · versie 0105 · 2016-06-06
Geldig voor: Model 906.132/134/136
Niet beschikbaar in “nl”; getoond in Engels.
Plaats
Functiegroep 2 Onderstel › 40 Wielen, wieluitlijning › 40.20 Wieluitlijning — Serie 906 (modellen 132, 134, 136)
EinPAS 20 Onderstel › 20.10 Uitlijnen › 20.10.20 Diagnose/controle/uitlijnen/afstellen — Serie 906 (modellen 132, 134, 136)
AR40.20-D-0322-03C
| Check caster and assign to tabular value
|
|
|
Test and adjustment values for caster
|
Number
| Designation
|
| Model 906.132/134/136
|
BE40.20-N-1001-20M
| Caster values, form
|
|
|
|
| See
| OF40.20-D-3000-00C
|
Test and adjustment values for caster
|
Number
| Designation
|
| Model 906.132/134/136
|
BE40.20-N-1002-20M
| Permissible difference in caster between right and left side of vehicle
| °
| 30'
|
Test and adjustment values for caster
|
Number
| Designation
|
| Model 906.132/134/136
|
BE40.20-N-1003-20M
| Absolute caster tolerance
| °
| 30'
|
1
| Measure level of front axle and rear axle on one side of the vehicle and find the specified value for the caster in the table.
|
2
| Determine actual caster values.
|
3
| Compare specified value for caster against actual caster value and determine whether the permissible tolerance is met.
|
|
| The caster cannot be adjusted but it must be checked to ensure the chassis geometry is correct.
|