ad0761p600045b

Oxygen sensor heater downstream of TWC - Check ME-SFI gasoline injection system electrics

Type ad · thema 07.61 · versie 0101 · 2003-06-10

Geldig voor: ENGINE 120 with CODE (494a) USA version

Niet beschikbaar in “nl”; getoond in Engels.

Plaats

Functiegroep 1 Motor › 07 Mengselvorming › 07.61 Benzine-inspuit- en ontstekingssysteem ME

EinPAS 15 Motor › 15.45 Motormanagement › 15.45.1 Basisinformatie

Geldt ook voor motoren/versnellingsbakken: 120 ***

AD07.61-P-6000-45B

Oxygen sensor heater downstream of TWC - Check ME-SFI gasoline injection system electrics

Scope of test

Tester/test connection

Operation/

prerequisite

Specified value

Possible cause/

remedy

1.0

Oxygen sensor on left downstream of TWC (G3/5) or on right downstream of TWC (G3/6)

Oxygen sensor heater

Actuation

12

(1.12)

N3/11

N3/12

25

(1.25)

Engine: at idle speed

Coolant temperature

> 80 °C

Allow engine to idle for approx. 2 min.

11 - 14 V

1.1

ME-SFI control module (N3/11) or (N3/12)

1.1

Power consumption G3/5 or G3/6

26

(1.26)

N3/11

N3/12

12

(1.12)

Ignition: ON

0.6 - 3.4 A

Lead

G3/5 or G3/6