AD07.16-S-2000-40A | Connection diagram, vacuum control unit for exhaust gas recirculation valve, testing pneumatics, CDI |
S07.16-4120-06
Connection diagram, vacuum control unit for exhaust gas recirculation valve
1 EGR valve vacuum control unit
Test description
Check vacuum control unit for exhaust gas recirculation valve for leaks. The actual values are read off via the vacuum tester.
Test connections
Connect vacuum tester to vacuum control unit for exhaust gas recirculation valve.
Execution of the test
Gererate vacuum using the vacuum tester and read off the display.