gf8370w4017a

Heat exchanger, location/purpose/design

유형 gf · 주제 83.70 · 버전 0102 · 1999-11-08

적용 대상: MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W '

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 83 에어컨 › 83.70 보조히터, 추가히터, 추가히터 — 시리즈 950 · 시리즈 952 · 시리즈 953 · 시리즈 954

GF83.70-W-4017A

Heat exchanger, location/purpose/design

28.8.96

MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W

Heat exchanger, location/purpose/design

W83.70-0020-12

2 Control module
3 Glow pin
4 Temperature sensor
5 Burner
6 Heat exchanger
7 Overheating sensor
8 Coolant circulation pump
9 Burner housing
10 Flame sensor
11 Combustion air blower

Location

GF83.70-W-4017-01A

Purpose

The purpose of the heat exchanger is to conduct the heat energy from the combustion gases in the combustion chamber and the coolant flowing through the heat exchanger insert:

The combustion gases heat the wall of the heat exchanger insert.

The coolant flowing along the outside of the heat exchanger insert absorbs the heat energy into the coolant circuit.

Design

The heat exchanger is designed using a double wall with the heat exchanger housing on the outside and heat exchanger insert on the inside. The inner wall of the heat exchanger insert forms the combustion chamber. The coolant flows through multiple coils around the outer wall of the heat exchanger insert. The temperature sensor as well as the overheating sensor are installed in the heat exchanger.

참조 문서